Can a door swing into electrical panel clearance?

110.26(A)(2) says “in all cases, the work shall permit at least a 90 degree opening of the equipment doors or hinged panels”. If front door was open, panel door could not open. My interpretation of NEC is panel behind door-swing is a code violation. Well, 110.26 does say that the work space shall be clear at all times.

What is clear floor area?

Clear floor spaces are typically 30″ x 48″ minimum unless blocked on all or part of three sides for more than half the distance. If blocked by objects or within an alcove, then the clear floor space increases from 30″ x 48″ to either 36″ x 48″ or 60″ x 30″.

Can Grab bars overlap door clearance?

Grab bars and other elements cannot overlap the door maneuvering clearance but can be located within the 8 inches max. … Elements, including those providing knee and toe space, cannot overlap or protrude into the maneuvering clearance required at doors and doorways.

IT IS IMPORTANT:  How much do roller doors weigh?

How far does a door swing into a room?

Designers and architects, including those at the New York Institute of Art and Design, recommend a minimum clearance of 30 inches in front of a door for furniture placement, and more if the door opening is larger. This clearance is in addition to the allowance for the swing of the door, if it swings into the room.

How much clearance is needed around an electrical panel?

Regulatory Requirements

The Occupational Safety and Health Administration (OSHA) and the National Electrical Code (NEC), require that electrical panels have a minimum of 3 feet (36 inches) of clearance and a minimum headroom of 6.5 feet or the height of the equipment whichever is greater.

How close can a door be to an electrical panel?

But, the width of the working space must allow for the panel door to open at least 90 degrees. The height of the working space must be at 6-1/2 feet. Other electrical equipment located above or below the panel cannot protrude more than 6-inches beyond the front of the panel.

What is the minimum pull side clearance at an accessible door?

Front approaches to pull side of swinging doors shall have maneuvering space that extends from the hinge side of the door to 18 inches (455 mm) minimum, 24 inches (610 mm) preferred, beyond the latch side of the door and 60 inches (1525 mm) minimum perpendicular to the doorway.

How much space do you need to turn a wheelchair?

For manual wheelchair users, the T-shaped turning space should be in a 60 inch square minimum space, with arms and base 36 inches wide. And for electric wheelchair, scooter, or reclining wheelchair users, the T-shaped turning space should be in a 94 inch square minimum space with arms and base minimum 40 inches wide.

IT IS IMPORTANT:  How do you hang a Christmas wreath on a plastic door?

Can handrails encroach on door clearance?

No, handrails and other elements cannot overlap door maneuvering clearances. However, the door maneuvering clearance can be offset up to 8” from the face of the door to accommodate wall thickness, casework, handrails, moldings, and other elements at doorways.

Can handrails protrude into door clearance?

No, door maneuvering clearances must be free of any overlapping objects, even those providing knee and toe clearance, which can interfere with maneuvering at doors and doorways.

Can door swing overlap turning radius?

Yes, doors can swing into turning space. … Yes, clear floor or ground spaces and turning space can overlap other required clearances, including other clear floor spaces, door maneuvering clearances, and fixture clearances.

Should a door swing left or right?

An inward opening door should swing in the direction needed to provide adequate passage. If it bumps or blocks passage because of a wall, barrier or other object when you open it, such as a toilet or cabinet, the door should swing in the opposite direction.